Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Three Phase
Speed: Speed
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GFP-200
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Canopy Color
Can Be Customized
Options
ATS, Silent Type, Trailer Type
Alternator
Stamford/Leory Somer/Yabo
Delivery Time
15-25days
Engine
Cummins, Perkins, Deutz, Lovol
Frequency
50/60Hz
Warranty
1 Year or 1000 Hours
Controller
Smartgen/Comap/Deepsea
Transport Package
Shrik Wrap or Wooden Box
Specification
3400*1200*1900
Trademark
XINYABO
Origin
China
HS Code
85021100
Production Capacity
3000PCS

Product Description

Rated power

Engine

Alternator

Control panel

20kw~1300kw

Cummins

Stamford

Leroy somer

Marathon

Mecc alte

ABB

Chinese alternators

Deepsea

ComAp

Harsen

Smartgen

8kw~1600kw

Perkins

68kw~504kw

Volvo

20kw~500kw

Deutz

220kw-2400kw

MTU

280kw-800kw

MAN

600kw-1800kw

Mitsubishi

50kw-650kw

Doosan Daewoo

2kw~2500kw

Chinese engines


100kVA 200kVA 300kVA 400kVA 800kVA 1000kVA Soundproof Diesel Generator Perkins Power Generator

 

Δ Standard Configuration of Perkins Open Type

1. Powered by Perkins engine

2. Leroy Somer alternator (Stamford, Meccalte for option)

3. Deepsea HGM 6110 control panel as standard, AMF Control Panel Deepsea DSE7320 & Smartgen HGM6120 for Option, ATS for Option

4) Chint breaker as standard, ABB, Schneider Breaker for Option

5) 8 Working Hours Base Fuel Tank (for the genset ≤ 650kVA prime, only Base Frame for other models)

6) Anti-Vibration Mounted System

7) Battery and battery switch

8) Industrial silencer and flexible exhaust hose

For open type, the genset will be much easier to maintain and repair with more durable performance and longer service life, so the cost performance is higher.

Δ More technical datas 


Our gensets compliance with all main standards, such as : GB/T2820, ISO8528,IEC34, CE, EPA Tier4 Standard
Prime output power: 5KVA - 2000 KVA
Rated voltage: 120V/240V, 220/380V, 230V/400V, 254V/440V etc.
Phase/connecting: 3 phase, 4wire.
Rated frequency: 50Hz@1500rpm, 60Hz@1800rpm
Alternator excited type: Brushless, self excited or PMG
Insulation: Class H 
Protection: IP21~IP23
Voltage regulation: AVR automatic control 1% 
Altitude above sea level: ≤1000 meters
Ambient air temperature: ≤40°C
Relative air humidity: ≤ 90%


Original U.K. ENGINE: 

Δ TECHNICAL DATA:
Technical Specification:
Generator Set Specification
Genset Model GFP-12.5KVA GFP-15KVA
Sient Open Silent Open
Frequency 50Hz 50Hz 50Hz 50Hz
Voltage 400/230V 400/230V 400/230V 400/230V
Phase 3 3 3 3
Prime Power (KW/KVA) 10/12.5 10/12.5 12/15.0 12/15.0
Stanby Power(KW/KVA 11/13.8 11/13.8 13.2/16.5 13.2/16.5
Weight And Demensions
Lenghth (mm) 1900 1300 1900 1300
width (mm) 850 700 850 700
Height (mm) 1350 1100 1350 1100
Weight (kgs) 630 390 680 430
Engine Specication
Engine Model 403A-15G1 403A-15G2
Prime/Standby power (kw) 12/13.2 13/15
Injection Indirect Indirect
Aspiration Naturally Aspirated Naturally Aspirated
No. of cylinders 3 3
Bore of Stroke (mm) 84x90 84x90
Displacement (L) 1.496 1.496
Cooling water water
Compression Ratio 22.5:1 22.5:1
Engine Oil capacity (L) 6 6
Coolant Capacity        ( In radiator) 6 6
Governor Mechanical Mechanical
Air Filter Dry Element Dry Element
Fuel comsuption at 50Hz at 50Hz
Average data (L/h) 3.1 3.8
100% Load (L/h) 3.7 4.8
75% Load (L/h) 2.8 4.0
50% Load (L/h) 2.0 2.9
Alternator Specification
Brand Leroy Somer Leroy Somer
Model  TAL-A40-C TAL-A40-D
Pole 4 4
Winding Connections Star Star
Insulation Class H H
Enclosure IP23 IP23
Voltage Regulater AVR AVR
Steady StateVoltage Regulater 1% 1%
Bearing single single
Controller System
Brand  Deepsea Deep Sea
Model  6120 6120
Δ GPC SERIES DIESEL GENERATOR SET POWER RANGE
50Hz
3 phase, 4 wires, 0.8PF, 1500rpm, 415-230V/240-115V
Genset Model Prime Power Standby Power Engine model Fuel consumption Genset Weight 
 Dimension
KW KVA KW KVA L/h (mm)  (kg)
GFP9-I  7 9 8 10 403A-11G1 3.0  1088x449x891 330
GFP9-II 7 9 8 10 403D-11G 2.6  1088x449x891 330
GFP13-I  10 13 11 14 403A-15G1 3.7  1138x456x950 390
GFP13-II 10 13 11 14 403D-15G 3.6  1138x456x950 390
GFP15 12 15 13 17 403A-15G2 5.0  1138x456x960 420
GFP20-I 16 20 18 22 404A-22G1 5.3  1285x477x973 470
GFP20-II 16 20 18 22 404D-22G 5.3  1285x477x973 470
GFP30 24 30 26 33 1103A-33G 7.1  1461x630x1130 750
GFP45 36 45 40 50 1103A-33TG1 10.7  1493x634x1166 770
GFP60 48 60 53 66 1103A-33TG2 13.9  1530x750x1300 770
GFP65 52 65 57 72 1104A-44TG1 14.8  1730x630x1166 840
GFP80-I 64 80 70 88 1104A-44TG2 18.7  1730x630x1166 950
GFP80-II 64 80 70 88 1104C-44TAG1 18.6  1750x650x1260 950
GFP100 80 100 88 110 1104C-44TAG2 22.6  1850x700x1200 1120
GFP135 108 135 119 149 1106A-70TAG1 38.0  2175x750x1522 1400
GFP150 120 150 132 165 1106A-70TAG2 38.0  2175x750x1522 1400
GFP180 144 180 158 198 1106A-70TAG3 40.2  2500x900x1500 1500
GFP200-II 160 200 176 220 1106A-70TAG4* 47.0  2530x900x1560 1640
GFP200-II 160 200 176 220 1306A-E87TAG3 46.0  2530x900x1560 1640
GFP225 180 225 198 248 1306A-E87TAG4 50.0  2283x900x1522 1725
GFP250 200 250 220 275 1306A-E87TAG6 54.0  2458x900x1532 1800
GFP275 220 275 242 303 1606A-E93TAG4 56.0  2800x950x1650 2200
GFP300 240 300 264 330 1606A-E93TAG5 61.0  2900x1000x1700 2700
GFP350 280 350 308 385 2206C-E13TAG2 75.0  3029x1120x1871 3020
GFP400 320 400 352 440 2206C-E13TAG3 85.0  3000x1120x1946 3150
GFP450 360 450 396 495 2506C-E15TAG1 99.0  3100x1120x1960 3300
GFP500 400 500 440 550 2506C-E15TAG2 106.0  3200x1120x1960 3350
GFP600 480 600 528 660 2806C-E18TAG1A 129.0  3600x1600x2100 3650
GFP650 520 650 572 715 2806A-E18TAG2 132.0  3600x1600x2100 3880
GFP750 600 750 660 825 4006-23TAG2A 157.0  3800x1800x2180 4500
GFP800 640 800 704 880 4006-23TAG3A 172.0  3786x1710x2100 4500
GFP1000 800 1000 880 1100 4008TAG2A 220.0  4582x2050x2500 7600
GFP1250 1000 1250 1100 1375 4012-46TWG2A 262.0  4497x2050x2500 9600
GFP1350 1080 1350 1188 1485 4012-46TWG3A 285.0  5200x2050x2400 9900
GFP-1500 1200 1500 1320 1650 4012-46TWG4A 316.0  5200x2050x2400 9900
GFP1500-2 1200 1500 1320 1650 4012-46TAG2A 305.0  4762x2160x2509 10000
GFP1710 1368 1710 1505 1881 4012-46TAG3A 354.0  5600x2100x2500 10000
GFP1850 1480 1850 1628 2035 4016TAG1A 383.0  5582x2300x3300 12000
GFP2000-I 1600 2000 1760 2200 4016TAG2A 434.0  5682x2300x3300 14000
GFP2000-II 1600 2000 1760 2200 4016-61TRG2 422.0  6050x2400x3000 15000
GFP2250 1800 2250 1980 2475 4016-61TRG3 470.0  6500x2500x3320 16000


Δ GENSET FEATURES 

1. Genuine Perkins  industrial diesel engine

2. Radiator 50°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, Yabo alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9. Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

Δ ENGINE FEATURES 

1. Genuine Perkins   industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily
100kVA 200kVA 300kVA 400kVA 800kVA 1000kVA Soundproof Diesel Generator Perkins Power Generator


Δ ALTERNATOR FEATURES

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, Yabo

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
100kVA 200kVA 300kVA 400kVA 800kVA 1000kVA Soundproof Diesel Generator Perkins Power Generator

Δ DIGITAL CONTROL PANEL

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

Δ STANDARD SUPPLY SCOPE
Exhaust silencer Flexible pipes Flange Base frame Main circuit breaker
Starting battery Battery wires Battery charger Float battery charger AVR
Cooling radiator Wires diagram Manual books Auto control panel Silent canopy

Δ OPTIONAL PARTS
Engine & Radiator Alternator part Electric part Fuel tank part Others
Water preheater PMG ATS External daily fuel tank Weatherproof canopy
Lub oil pre-heater Anti-condensation heater Synchronization panel Automatic fuel pump Mobile trailer
Spare parts Parallel droop ABB breaker Oil drain pump  Containerized


100kVA 200kVA 300kVA 400kVA 800kVA 1000kVA Soundproof Diesel Generator Perkins Power Generator


Δ FAQ (FREQUENCY ASKED QUESTION)
Question: What's your warranty period?
Answer: Our payment terms is 1 year or 1000 running hours whichever comes first.
But based on some special project, we can extended our warranty period.

Question: Does your generators has global warranty?
Answer: Yes, most of our products like Cummins, Perkins, Doosan power generator enjoy the global warranty service.
And the alternator we use like Leroysomer, Stamford, marathon also enjoy the global warranty service, so you do not need to worry about the aftersales service.

Question: Do you accept OEM/ODM service?
Answer: Yes, we can accept OEM & ODM service.

Question: What's your payment terms?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment.
Or 100% irrevocable confirmed L/C at sight.Question: What's your delivery time?
Answer: Our normal delivery time is 15 - 25 working days.
But if your order is some special engine and alternator, then the delivery time is longer. 

Question: What's the MOQ?
Answer: 1 Set

 

 

 
 
 
 

Send your message to this supplier

*From:
*To:
avatar Mrs. Hebe Wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed