Customization: | Available |
---|---|
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Engine of CUMMINS EG120 Natural Gas Generator Set |
|
Engine Model | CUMMINS 6CT |
Type | 6 cylinders in line |
Bore * Stroke (mm) | 114*134 |
Displacement(L) | 8.3 |
Compression ratio | 10.5:1 |
Rated speed(rpm) | 1500/1800 |
Inlet type | Exhaust Turbocharger/Air-Air Intercooler |
Cooling type | Cooling water tank |
Fuel System | Low and high pressure |
ESC Type | Special for U.S. GAC natural gas |
Ignition sequence | 1-5-3-6-2-4 |
The allowed maximum speed (Natural gas supply closed at this time) | 2160 rpm |
The allowed maximum rotating speed (The ignition system shut down at this time) | 2160 rpm |
Oil Capacity | 23.8 L |
Cooling water capacity | 24.3 L |
Maximum engine back pressure | 10.2 kpa |
Gas consumption(m3kw·h) | <0.3 |
Rough oil consumption(g/kWh) | <1.2 |
Radiator and oil cooler heat | 40KW |
Exhaust pipe heat radiation | 46KW |
Engine thermal radiation | 8KW |
Alternator thermal radiation | 2KW |
Cooling water temperature | 95 Deg C |
Oil temperature | <120 Deg C |
Exhaust pipe heat energy (above 120 º C section) | 110KW |
Exhaust temperature (before vortex ) | 650±15 Deg C |
Exhaust Flow | 1050 m³/h |
Fan exhaust flow | 7 m³/s |
Noise level from 1 m | less than 100 db(A) |
Alternator of CUMMINS EG120 Natural Gas Generator Set |
|
Alternator Model | Engga EG225L-120N |
Excitation Method | Brushless Permanent Magnet |
Winding pitch | 2/3 pitch |
Number of poles | 4 |
Bearing number | 1 |
Stator Windings | 12 ends |
Insulation Class | H class |
Protection class | IP 21 or IP 23 |
Load type | Continuous operation |
AVR Model | WT-2 |
Alignment | Fly wheel |
Temperature Range | Less than 125 degrees Celsius |
Overload Capacity- the percentage of rated power | 110% |
Waveform distortion rate, no-load | <5% |
Voltage Regulation Mode | AVR |
Voltage Regulation Range | ±5% |
Steady State Voltage Regulation | ±1% |
No-load line voltage sine wave distortion | <2% |
Telephone interference factor (TIF) | < 50 |
CUMMINS EG120 Natural Gas Generator Set |
|
Rated Output(KW) | 120 |
Standby Output(KW) | 132 |
Voltage(V) | 400 |
Current(A) | 216 |
Size(mm) | 2500*950*1535 |
Approximate weight(KG) | 1400 |
Emission levels (Nox) | Euro II emission(mg/m³) |
Naturally aspirated engine intake air temperature | None |
Air temperature before entering the air to air intercooler | 82-87(Deg C) |
Air temperature after entering the air to air intercooler | 35-42(Deg C) |
Rated Power @ 0.8 power factor (w / pump s and w / o fan) | 120KW (continuous operation) |
Total energy input (100% load) | 332(KW) |
Electrical efficiency | 36.20% |
Thermal efficiency | 87.90% |
Control panel(Deepsea or others) | Synchronizing Control, Multilingual Mode Digital Control, Diagnostic Function, Direct Text Indicate of Faults, MOBUS Communication Protocol, Compatible Communication, Exchange Telecommunications, Wired Control Data Output, Automatic or manual start |
Technical Data | |||||||
Genset Model | Prime Power (KW/KVA) | Engine Model | Clylinders | Bore×Stroke (mm) | Gas Consumption Rate (m3/kw.h) | Displacement (L) | |
KW | KVA | ||||||
NG2-30KW | 30 | 37.5 | 1004NG | 4 | 100×127 | 0.5-0.3 | 3.99 |
NG2-40KW | 40 | 50 | 1006NG | 6 | 100×127 | 0.5-0.3 | 5.98 |
NG2-90KW | 90 | 112.5 | 1006-G6TAG | 6 | 100×127 | 0.5-0.3 | 5.98 |
NG2-100KW | 100 | 110 | R615 | 6 | 126×130 | 0.5-0.3 | 9.7 |
NG2-120KW | 120 | 132 | R615 | 6 | 126×130 | 0.5-0.3 | 9.7 |
NG2-150KW | 150 | 165 | R618 | 6 | 126×150 | 0.5-0.3 | 11.2 |
NG2-160KW | 160 | 200 | D11 | 6 | 128×142 | 0.5-0.3 | 10.96 |
NG2-220KW | 220 | 275 | D15 | 8 | 128×142 | 0.5-0.3 | 14.62 |
NG2-320KW | 320 | 400 | D22 | 12 | 128×142 | 0.5-0.3 | 21.93 |
NG2-440KW | 440 | 500 | D30 | 16 | 128×142 | 0.5-0.3 | 29.24 |
ACCEPTABLE WORKING CONDITIONS: | |
Ambient temperature : | -40°C~+45°C |
(antifreeze or hot water needed for below -20°C) | |
Relative humidity: | <90%(20°C) |
Altitude: | ≤1000m |
NORMAL WORKING CONDITIONS: | |
Genset can run at rated power on the conditions: | |
Atmospheric Pressure: | 100kPa |
Ambient Temp: | 20°C |
Relative Humidity | 30%. |
APPLIED GAS: | Natural Gas, Biogas,Oil field gas |
Acceptable gas pipeline pressure: | 0.8~450kPa |
Engine inlet pressure: | 0.8~5.0kPa (80~500mmH2O) |
CH4 content: | for natural gas ≥75%; for biogas≥40% |
Sulphur content: | ≤400ppm |
Gas heat value: | ≥5500kcal/Nm3 (23MJ/Nm3 ) |
Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.) |
1. Brand new gas engine, 90% parts include engine body , crank shaft, cam shaft, piston, cylinder head, etc made by Cummins with best quality |
2. Brand new brushless France Leroy Somer alternator |
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H |
4. Radiator for 40°C/50°C ambient temperature |
5. Ignition system adopted USA ALTRONIC |
6. Emergency stop mounted |
7. Battery,Battery cable and Battery charger |
8. Standard tool box |
9. Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw ) |
10. Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand) |
11. Testing report and maintenance manual. |