• Diesel Generator Sets with 400kw/500kVA Perkins Engine
  • Diesel Generator Sets with 400kw/500kVA Perkins Engine
  • Diesel Generator Sets with 400kw/500kVA Perkins Engine
  • Diesel Generator Sets with 400kw/500kVA Perkins Engine
  • Diesel Generator Sets with 400kw/500kVA Perkins Engine
  • Diesel Generator Sets with 400kw/500kVA Perkins Engine

Diesel Generator Sets with 400kw/500kVA Perkins Engine

Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Three Phase
Speed: Speed
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GF2/3P-400
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Transport Package
Wooden Case
Trademark
XINYABO
Origin
Fujian, China
HS Code
85021200
Production Capacity
1000sets/ Per Month

Product Description


Diesel Generator Sets with 400kw/500kVA Perkins Engine
The main parameters of the engine

Genset Model
GF3P-500KVA
   
 Engine Brand PERKINS
Engine Model 2506C-E15TAG2
Prime power 435KW/543.75KVA
Standby power 451KW/563.75KVA
Intake type Turbocharged, air-to-air chargecooled
Engine Structure 6-cylinder,4-stroke,Vertical in-line
Cooling Method Water cooled
Combustion system Direct injection
Bore×Stroke (mm ) 137x 171
Total Displacement (L) 15.2
Total coolant capacity (L) 58
Total lubrication system capacity (L) 62
Direction of rotation Anti-clockwise,viewed on flywheel
Compression Ratio 16:01
Rotate Speed(rmp) 1500/1800
Prime Fuel Consumption (g/KW.h) 208
Frequency Control Ways Electric fule Injection (EFI)
Starting Method By DC 24V electrical starting
Alternator Brand STAMFORD
Model HCI544C
Type brushless (AVR automatic voltage regulating)
The connecting way of the phase     three phases four lines
Insulation degree H degree
TIF <50
THF <2%
The factor of rated power ≤±1%
Grading Protection IP23
Unit parameters
Power 400kw/500KVA
Rated voltage 400V/230V
Rated current 720A
 Rated frequency 50 HZ
The factor of rated power 0.8
The regulating rate of instantaneous voltage ≤-15%/ +20%
The regulating rate of steady voltage ≤±1%
The time of steady voltage ≤3sec
The waving rate of voltage ≤0.5%
Voltage waveform distortion degree ≤8%
The  regulating  rate of steady frequency ≤5%
The regulating rate of instantaneous frequency ≤-10%/+12%
The time of steady frequency 3sec
The waving rate of frequency ≤1.5%
The waste of fuel with full load 211g/kw.h
Size(mm) 4050*1200*2100
Weight(kg) 3760
     
       
     
     
     
     
     
 

 

Standard supply:

1) Powered by heavy duty industrial diesel engines, famous engine brand can be chosen.

2) Brushless alternator,single bearing,flange connection,IP23,H insulation class,with AVR.

3) Auto control panel with LCD display.

4) Engine mounted battery-charging alternator,Genset with battery charge of main supply.

5) Circuit Breaker,Exhaust Silencer.

6) Copper Radiator for 40°C ambient temperature and double-deck cooling,with fan guard and front guard.  

7) Anti-vibration pads fixed between engine/alternator and base frame to ensure the compete genset running stable.

8) Skid-mounted bottom 8 hours fuel tank.

9) Extemal recessed emergency stop button for extra safety.

10)Optional:Soundproof,ATS(automatic transfer switch),AMF panel,Trailer,Parallel system.

 

Optional:

--Automatic Transfer Switch

--Soundproof Canopy

--Under base tank

--Oil filter

 


AMF Control Panel- ComAp AMF20 Or DSE7320
Brand Deepsea/ComAp
The control module gives digital readouts of:
Generator voltage;
Output frequency;
Engine speed;
Battery voltage;
Engine hours run.
The control module has indicators for failure
information:
Overspeed/underspeed,
Emergency stop
Low oil pressure;
High water temperature
Failure to start
Battery charger failure
Automatic shutdown occurs under:
Low engine oil pressure;
High engine water temperature;
Overspeed/underspeed;
Failure to start after three attempts.

Diesel Generator Sets with 400kw/500kVA Perkins Engine


Diesel Generator Sets with 400kw/500kVA Perkins Engine



Diesel Generator Sets with 400kw/500kVA Perkins Engine

FAQ(Frequently Asked Question):

1.What is your warranty period?

 Our payment terms is 1 year or 1000 running hours whichever comes first. But based on some special project, we can extended our warranty period.

2.Does your generator have global warranty?

 Yes, most of our products like Cummins, Perkins, Doosan power generator enjoy the global warranty service. And the alternator we use like Leroysomer, Stamford, marathon also enjoy the global warranty service, so you do not need to worry about the aftersales service.

3.Can you accept OEM?

 Yes, we can accept OEM.

4.What is your payment  terms?

We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment or L/C at sight, L/C deferred payment terms or west union. 

5.What is your delivery time?

Our normal delivery time is 2 to 5 weeks. But if your order is some special engine and alternator, then the delivery time is longer.  

 

Contact information:

Ms. Hebe Wang 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now